Ambul ventilator 6000S

This product is no longer available.

Terms and Conditions
Lead time 6-8 weeks, built to order 


  • Main unit, ventilation hose, patient valve-mask

  • Portable and easy operation

  • Innovative voice-guided direction

  • Tidal volume range: 100- 1500ml


This product is not Approved by Health Canada

Portable Invasive / Non-invasive ventilator

Suitable for vehicle transport, long-distance transport, hospital transport, and wilderness rescue.


  • TFT display of airway pressure and ventilation mode

  • 3 ventilation modes. IPPV, Assisted control and Manual control

  • Li-ion rechargeable battery with more than 10 hours of working time

  • Air Mix option for 60% 02

  • 3 knobs for flexible parameters adjustment


Device categoryClass Ilb
Degree of Protection against
Electric Shock
BF
Degree of protection against
Ingress of Liquids
IPX4
Degree of Protection against 
Hazards of Explosion
Ordinary equipment, without
protection against explosion; not for
use with flammable anesthetic
Mode of Operation:Continuous running equipment
Dimensions WxHxD in mm240x 120x 100mm include
connectors
WeightApprox. 1.3kg
Display2.4" TFT color display resolution
ratio: 320.'240
Pressurized gas connectionExternal thread 9/16-18
Ventilation hose connectionExternal diameter 15mm/Internal
diameter 20mm
Operating: Temperature range Humidity
Air pressure
-20'C to +50°C
15% to 95%
70 kPa to 110 kPa
Store/transport:
Temperature range
Humidity
Air pressure
--40°C to +50°C
595%
70 kPa to 110 kPa
Power supplyAC: 100 to 240V: 1.5 to 4A: 50/
60HZ
DC : 12 V Adapter
Work currentImin=0.3A; Irn..0.6A
Battery: Standard
Work temperature
Lithium battery 7.4V: 3400mAh :
operating time: more than 10 hour
-20°C to +55°C
Ventilation modesIPPV: A/C: CPR
Operating pressure2.7 to 6.0 bar
Required gas supply
Standard gas supply:
-Supply pressure
-Drawn flow
Optimal gas supply:
-Supply pressure
-Drawn flow
Non-recommended gas supply:
-Supply pressure
-Drawn flow
At least 2.7bar
At least 70 1/min Oxygen(ATPD)
At least 4.5bar
At least 100 1/min Oxygen(ATPD)
Less than 2.7bar
Less than 80 l/min Oxygen(ATPD)
Insp-exp. RatioConstant 1:1.67
Minute volume(MV)Continuously variable from 3 to 20
Umin(ATPD)
Ventilation frequencyContinuously variable from 5to 40
min'
02 concentrationNo Air Mix 100% and Air Mix (see
page 42)
MV tolerances±20%
Max. ventilation pressure20 to 60 mbar
Safety airway pressure575 mbar
Pressure gauge accuracy0 to 60 mbar Deviation ±5%
Trigger sensitivity-2 mbar Deviation ±0.5mbar
Reusable ventilation hoseSpiral silicone
Patient valve resistance:
Inspiration
Expiration
Emergency air intake
<6 mbar at 30, 60 1/min
<6 mbar at 30, 60 1/min
<6 mbar at 15. 30 1/min
Respiratory compliance100 ml/cmH2O
Voice alarm mute time120s
Voice prompt languageSupport five languages, default
Simplified Chinese