Aeonmed Respiratory Ventilator VG70

This product is no longer available.

Terms and Conditions
Lead time 6-8 weeks, built to order 


  • Comprehensive ICU ventilator including BIVENT and PRVC

  • Compact, large capacity battery, no air compressor, intra-hospital mobility

  • Flexible device configuration: equipped with a trolley, bed or ceiling pendant mount

  • Unique metal-based, autoclavable, heated exhalation valve

    The VG70 is a comprehensive transportable ICU ventilator including lung protective ventilation modes such as BIVENT and PRVC. The VG70 has flexible configuration allowing for trolley, bed or ceiling pendant mount. As a cost effective solution the VG70 has a metal based autoclavable exhalation valve with a nonconsumable design built in flow sensor and its ventilation software is upgradeable with the available USB port.The VG70's optimal ventilator synchrony leads to greater patient comfort, the Leak compensation system precisely controls the tidal volume of each breath delivered to the patient by adjusting compensation dosage automatically. 


The VG70 is an optimal combination of invasive and non-invasive ventilator. As noninvasive ventilation is used increasingly in a wide range of clinical situations, we offer a dual solution. The VG70 combines the advantages of a flexible noninvasive ventilator with a full-featured invasive ventilator for the ICU.

Optimal patient-ventilator synchronization, increased patient comfort

  • The Unique Leak Compensation System - Keep precise control on the tidal volume of each breath delivered to the patient by adjusting compensation dosage automatically

  • Advanced Trigger Technique - Enhanced sensitivity, to avoid spurious triggering

Safe Ventilation Through Whole Treatment Phase Initial Treatment Phase

  • Noninvasive ventilation mode associated with decreased intubation rates, shortened patient stays, improved patient comfort, and a reduced risk of cross-infection

  • Preset patient’s height and IBW. Reduce clinician’s workload

Stable Condition Phase

  • PRVC and BIVENT employ lung-protective strategies, delivering intelligent ventilation

  • Comprehensive lung mechanics monitoring include compliance, airway resistance, PEEPi and time constant

  • Three waveforms & three loops with user-friendly display provide a continuous monitoring of the patient’s condition

Weaning Phase

  • Various ventilation modes enhance the weaning process

  • The unique trigger and leakage compensation system safeguard each and every patient breath resulting in smooth and comfortable breathing, avoiding extra workload on the patient and promoting recovery

  • RSBI and WOB provide accurate reference for weaning

Rehab Phase

  • Data export port provides connection to hospital monitors and Patient Data

Management Systems

  • Provides pressure support for the patient when spontaneous breathing is present

  • Upgradeable ventilation system software, with an available USB port


Technical Specification



Ventilation Modes 

                                                              
VCV(A/C) PCV(A/C) PRVC SIMV(VCV)+PSV
SIMV(PCV)+PSV SIMV(PRVC)+PSV SPONT/CPAP+PSV
BIVENT+PSV NIV/CPAP NIV-T NIV-S/T

Parameters 

Tidal Volume:                  
20~2000 ml
Respiration Rate:
1~80 bpm
Tinsp:
0.2~9 s
Tslope:
0~2 s
Tpause:
0~4 s
I:E Ratio:
1:10~4:1
FiO2:
21%~100%
Trigger Sensitivity:
Pressure (-20~0 cmH2O, above PEEP)
Flow (0.5~20 LPM)
PEEP:
0~35 cmH2O
Psupport:
0~70 cmH2O
Pinsp:
5~70 cmH2O

Special Procedures 

                                                      
Apnea Ventilation Smart Suction Manual Breath
Insp/ Exp Hold ETCO2 Measurement
Nebulization Wave form Freeze

Monitoring 

Pressure Value:                                
Ppeak, Pplat, Pmean, Pmin, PEEP
Volume / Flow Value:
Vti, Vte, MV, MVspont
Time Value:
ftotal,fspont, I:E
Real Time Curves:
Pressure-Time, Flow-Time, Volume-Time wave forms
Pressure-Volume, Volume-Flow, Flow-Pressure loops
Gas Monitoring:
FiO2, ETCO2
Calculated Values:              
Compliance(C)
Resistance(R)
MVleak
RSBI
WOB
PEEPi

Alarm 

                                                                
Paw high / low MVe high / low Circuit disconnnect
FiO2 high / low Inspiration / Expiratory tidal volume low
High Respiration Rate Apnea AC Failure Nebulizer On
Low Battery Air /O2 supply down High / Low PEEP
Leakage out of range Occlusion

Technical Data 

Screen:
12〞TFT color touch screen (detachable)
Supply Gas:
O2, 0.28~0.6 MPa
Power Supply:
AC100~240 V, 50 Hz/60 Hz
Communication Interface:
RS-232 Port, Nurse call Port, Ethernet Port
Dimension (WxDxH):
322 mm x 375 mm x 366 mm (Main Unit)
547 mm x 675 mm x 950 mm (Cart)
Weight:
12.5 kg (Main Unit)
25 kg (Cart)

Remark: Above configurations include standard and optional. Please check price with your ASP sales representative.