Shenzhen Yamind Ventilator DM28

This product is no longer available.

Terms and Conditions
Lead time 6-8 weeks, built to order 


Application:

  • Pneumology Neurosurgery,

  • Neurology

  • Sleep clinics,

  • Chest Pain Center etc.


This product is not approved by Health Canada

    The first one adopted the interactive design solution to visualize treatment data and to enhance operating experience. In addition, with upgraded algorism, treatment experience and patienct compliance are highly improved.


Application:

Pneumology Neurosurgery, Neurology, Sleep clinics, Chest Pain Center etc.


  Technical Specification                                                                                                                    
 Type of ventilationType                                      Bi-level Continuous Positive Airway Pressure
Usage scenario
Application
Hospital or home
Adult weigh over 30kg, suffering from OSAHS or COPD
 Screen5.0" LED display; Touch control
 Therapa ModeSCPAPS/TT
 Pressure range2-30cmH2Opressure increment 0.2cmH2O
 Single fault≤40cmH2O
PressureStatic pressure deviation
Static pressure stability
±0.5cmH2O
±0.5cmH2O
 Pressure display accuracy±2% full scale+ 4% actual reading
 Pressure setcmH2O29,617,225
Max flow volumeOutput pressure
cmH2O
18,616,224
 Output pressure average
L/min
30606060
SpecificationInspiratory pressure (
IPAP)
4-30cmH2O
Expiratory pressure
(EPAP)
2-25cmH2O
Start pressure2cmH2O- EPAP
inhalation time0.515s
delayed pressure0-60min
Inspiratory sensitivity1-5 level
Expiratory sensitivity1-5 level
Exhalation release1-3 level
Inspiration rate1-3 level
Exspiration rate1-3 level
Target tidal volume100-2000ml
Humidification1-6 level ( ≦ 70 )
Auxiliary functionPressure & P95 real-time curves,  AVAPS control ( 100 - 2000 ml), automatic leakage compensation, altitude compensation, auto-start , accessories replacement reminder, data storage, auto pressure titration, events monitor
( AHI),
 Parameter  moniteredInspiration and expiration ratio, air leakage volume, respiration rate, tidal volume, munite ventilation, real-time inspiratory/expiratory pressure, AHI, P95, treatment mode, usage time, etc.
ReminderPower failureair leakage, humidifying temperature high, high leakage, lid or tubbing of humidifier fall off, high pressure, SD card error, low tidal volume, low munite ventilation 、 high inspiration pressure, low expiration pressure, high or low respiration rate, etc.
 AccessoriesMicro SD cardStandard4G storage
Tubingφ22mm>1.2m
MaskFM1A type face mask
 Noise≤30dB
 Humidity output≥10mgH2O/L