BMC Medical Ventilator Y30T
This product is no longer available.
An intelligent technology, featured in the RESmart GII Y/U series
Delivers an automatic solution for patients with OSA and/or respiratory insufficiency
Aligned with the same platform as the RESmart GII BPAP system
Adapts pressure automatically to the patient's needs and provides a better synchronization
The Resmart Y-30T BIPAP System Machine is intended to provide non-invasive ventilation to patients with complex sleep apnea (OSA) institutional Respiratory insufficiency. It is intended for adult patients by prescription for in home or hospital institutional use. Tidal volume function with additional comfort features offer effective performance. The Y-30T offers each patient personalized ventilatory support
- Pressure support automatically adjusts according to target volume as to improve hypopnia ventilation
- Real time monitoring includes pressure, flow, minute ventilation (MV), tidal volume, and pulse
- Advances leak compensation promises adequate volume support Ti Control, IE Sense and Rise time guarantee
- Better ventilation synchronization
Bi-level ventilator technical parameter table | |||
Ventilator type | Ventilator type | Electric control | |
Scope of application | Treatment and titration of patients with sleep apnea-hypopnea syndrome, severe snoring, and respiratory insufficiency. | ||
UI | 3.5-inch LED screen, English operating system | ||
* Ventilation mode | CPAP, S, S / T, T | ||
Pressure range | Pressure range | 4-30cmH2O (± 0.5cmH2O) | |
Pressure accuracy | ± 0.5cmH2O | ||
parameter settings | Delayed boost | 0-60min, setting the Timing interval 5min | |
Initial pressure | 4cmH2O-treatment pressure / respiratory pressure setting | ||
Treatment stress | 4-20cmH2O (in CPAP mode) | ||
Target tidal volume | 150ml-1500ml, on / off | ||
Respiratory rate | 3-40 times / minute | ||
Inspiratory time | 0.3 - 3.0 sec | ||
Backup frequency | On / off, default value 10 | ||
Pressure rise time | 1-4 omit gear | ||
Humidifier | 1-5 total 5 levels adjustable | ||
* Titration function | Support manual and automatic pressure titration, built-in remote wireless communication module, complete single and dual level switching at will during the titration, and supports | ||
Auxiliary function | Automatic leak compensation, automatic startup, automatic shutdown, delayed shutdown, screen backlight adjustment | ||
Monitoring parameters | Pressure, tidal volume, breathing rate, minute ventilation, leak volume, inspiratory time, blood | ||
Wave curve | Pressure-time waveform, flow-time waveform | ||
Alarm prompt | Tubes and masks falling off, air leakage prompts, power interruption, treatment machine failure, humidifier failure, low voltage, high breath rate, low breath rate, low minute ventilation, blood , replacement of filter cotton, SD card full Reseat SD card | ||
* Data management | Network data | BMC + Respiratory Health Management Cloud Platform | |
SD card data | RESmart data analysis software | ||
Accessories | SD card | Standard | |
SD card slot | Standard | ||
hose | φ22mm, length is 1.8m | ||
Mask | |||
noise | ≤30dB | ||
Environmental conditions | when using it | During transportation and storage | |
temperature | 5 C - 35 C | 20 C - 55 C | |
Atmospheric pressure | 760-1060hPa | 760-1060hPa | |
operating hours | ≥8 hours | ||
Power requirements | AC voltage | 100-240V | |
frequency | 50Hz / 60Hz | ||
input power | ≤2A | ||
Waterproof level | IP22-anti-drip device | ||
Instrument size | 290mm × 180mm × 134mm | ||
weight | 1.5kg (excluding humidifier) 2.5kg (including humidifier) |