Invasive Respiratory Ventilator SWISS Made PERISO MGPV Plus (+) Ventilator
This product is no longer available.
The PERISO MGPV+ model is based on the MGPV which was developed for the Swiss Armed Forces as an emergency device in the face of Covid-19 pandemic.
Can be used invasively and noninvasively.
The PERISO the MGPV+ is a fully functional Critical Care ventilator.
High measuring accuracy.
Low maintenance costs.
The MGPV+ is designed to be used in ICU and also on pediatric patients. It is a multi-functional ventilator, meaning invasive and non-invasive which can be used with a tracheal tube or with a mask.
Adaptive software of the MGPV and MGPV+ is user-friendly and modes can be added and customized.
Advantages of the MGPV and MGPV+
1. high measuring accuracy
2. short response times
3. low risk of injury resulting from excessive lung pressure
4. minimal risk of system failure
5. easy to handle
6. affordable price
7. low maintenance costs
8. can be produced in large quantities
Software to Hardware Ratio:
in conventional ventilators: 20%: 80%
in MGPV and MGPV+ 80%: 20%
therefore the risk of system failure is, by a multiple, lower, and the risk
of failure, very unlikely because the software is infinite.
The adaptive software of the MGPV+ ICU ventilator is user friendly,
a number of settings can be made on the 10-inch display. With a simple
swipe of the finger over the image of the patient, his body volume can be
modified and the software makes the necessary settings.
ABA Adaptive Breath Assistant:
Due to Artificial Intelligence and a number of sensors which perform
measurements in the immediate vicinity of the lungs, the ABA system
reacts to the patient and does not work against his natural respiratory
drive. The system protects the patient from injuries associated with
artificial ventilation.
Learn more? Download the pdf document.
PARAMETER |
PERISO MGPV PLUS |
Ventilator Mode |
CPAP, CPPV, CMV, APRV, IPAP(Absolute), NIV, NPPV, PC |
Type of patient |
Adult Adolescents Paediatric |
Breathing Rate |
12/min a 30/min |
Inspiratory Time |
0.9 s - 2.5 s |
Tidal Volume (TV) |
0.3 - 2.0 L |
Inspiratory Pressure |
2 - 40 mbar |
PEEP |
0 - 25 mbar |
FiO2 |
20 - 100 vol % |
Inspiratory End Criterion |
PIP Control |
Triggering |
Adaptative Breath Assistance (ABA) Dynamic reaction before the patient’s response |
MONITORING |
|
Air pressure Measuring |
Yes |
Tidal Volume |
Yes |
FiO2 |
Yes |
EtCO2 |
Yes |
I:E |
1:10 - 4:1 |
MVleak |
Yes |
PEEPintrinsic |
0 - 25 mbar |
BPM |
12 bpm - 30 bpm |
PIP |
Yes |
Safety lock Parameters |
Yes |
Graphics |
Volume /Time, Pressure-/Time |
Alarms |
|
Airway Pressure |
Yes |
Expiratory Volume |
Yes |
Tidal Volume |
Yes |
PEEP |
Yes |
Air leaks |
Yes |
Failure in oxygen supply |
Yes |
Failure of power supply |
Yes |
Low battery |
No |
Apnea |
No |
Spontaneous respiratory rate (RPR) |
Yes |
FiO2 |
Yes |
Gas Temperature |
No |
Patient disconnected from ventilator alarm |
Yes |
PIP |
Yes |
Airway occlusion |
Yes |
Filter Alarm |
Yes |
Acoustic alarm signal |
Yes |
Visual Indicator of Alarm |
Yes |
Performance data |
|
Response time of the valve |
< 5 ms |
Control Systems |
Pressure Control |
Opening pressure of the safety valve |
100 m.bar |
Leakage Compensation |
Up to 60L/min |
Operating Data |
|
Power Consumption |
35 VA |
Battery |
External. Possibility of connection to the main electric network and the emergency network (External UPS or Hospital Emergency Network). |
Range of turbine replacement |
No |
Warranty |
2 years |
Gas supply |
4 bar - min 2.5 bar max 8.0 bar. No compressor is required |
Equipement and Accessories |
|
Humidifier |
Not required. A self-washable bubbling system with sterile water humidifies the dry oxygen. |
Patient circuit |
Reusable and sterilizable |
Antimicrobial filter |
Yes (Replace per patient) |
Mucosae drainage system |
Reusable sterilizable |
Endotracheal tube |
Yes (Replacement per patient) |
Air compressor |
Not required |
Additional Information |
|
Functionality without an interface |
Pressure can be modified in adult and paediatric patients without the need for an interface. The internal software performs the control of ventilation |
Valves |
Dynamic Flow Valves |
Suitable for the ICU ( Intensive Care Unit) |
Yes |
Interface |
Highly intuitive and efficient |