Programmable AC power source for Flux system

US $ 2,031.00 US $ 2,031.00 2031.0 USD

US $ 2,031.00

    This combination does not exist.

    Add to Cart

    • Max Power: 500VA
    • Size: 4U
    • Weight: 30kg
    • Input Voltage (50/60Hz): 1Ø2W 110V ±10% 1Ø2W 220V ±10%


    Model we use in our flux system with the integrating sphere   Programmable AC power source
    Phase Model Max Power Output Current Size Weight Input Voltage (50/60Hz)
    0~150V 0~300V
    ASP-CF-0500EP1P 500VA 4.2A 2.1A 4U 30kg 1Ø2W 110V ±10% 1Ø2W 220V ±10%

    series Programmable AC power source

    General Specifications :      
    Output frequency FIx : 50Hz / 60Hz / 400Hz ; Adjustable : 40.00~500.0Hz
    Frequency resolution 0.01Hz (40.00-99.99Hz) , 0.1Hz(100.0-999.9Hz)
    Frequency accuracy ±0.01 %
    Frequency regulation Fix : ±1Count ; Adjustable : ±0.01Hz at 40.00-99.99Hz , ±0.1Hz at 100.0-999.9Hz
    Frequency temperature effect 50 ppm / ℃
    Frequency response 40Hz~500Hz ( ±1db )(at output voltage 80% Full scale no load)
    External input level 40.00Hz ~500.0Hz  ( 3.0Vrms Full scale) (optional)
    Output voltage Standard : 0~150V / 0~300V Optional : 0~150V / 0~300V / 0~600V (Special voltage on request)
    Voltage temperature effect ±0.2% / ℃
    Output T.H.D. ≦0.25% (at 120V-50/60Hz ) (0.1%/100Hz) ( at Resister Load ,PF=1,THD-R measurement ) (to 80kHz BW)
    Load regulation ±0.2% (at 50/60Hz , Resistor Load , PF=1 ,0.2%/100Hz)
    Line regulation ±0.2% (ACV± 10% ; THD≦2% ; Frequency ± 5%) (at 80% fullscal ; Load=0~50% ; PF=1)
    Allow crest factor of load current 2.5(at full load) (Rated current)
    Max. peak current 5 times of Rated Current (1000mS)
    Power factor of load 0.5~1(lead or Lag)
    Output voltage ramp time 0.1sec ~ 99.9sec
    Line drop compensation ≦ 5V
    Set accuracy Voltage ≦0.1% ± 2C (at 50/60Hz ; 0.05% / 100Hz) Frequency ≦0.05% ± 1C (at 50/60Hz ; 0.05% / 100Hz)
    Transient Response 100 micro sec
    Circuit Linear Amplifier Type
    Efficiency >50% (at 80%fullscal voltage ; Rated current) (watt efficiency)
    S/N Ratio More then 75dB(At Rated Output Voltage)
    DC drift < ±1mV
    Protections Function
    • Over voltage protection ,
    • Over current protection(120%) ,
    • Line input over/under voltage protection (±15%) ,
    • ±Sense cable loosen protection or compensation voltage> 5V ,
    • Over temperature protection ,
    • Output waveform CLIP alarm
    Cooling system Forced air-cooling type
    Operating Temperature/Humidity 0 ~ +45 ℃ / 10 ~ 90%RH
    Insulation Resistance 10Mohm .500VDC(line input terminal to casing)
    Acoustic Noise 70~80dB At 1 Meter Distance
     
    Functions Resolution (4 digital) Accurate
    Frequency Meter 0.01Hz / 0.1Hz Auto Range ±0.1% reading ± 2C ± 0.05%/100Hz
    True RMS Voltage Meter 0.1V ±0.2% reading ± 0.3% Full scale ± 2C ± 0.1% / 100Hz
    True RMS Current Meter 1mA / 10mA or 10mA / 100mA  Auto Range ±0.4% reading ± 0.3% Full scale ± 3C ± 0.1% / 100Hz
    Watt Meter 0.1W / 1W  or  1W / 10W  or  10W / 100W   Auto Range ±0.2% reading ± 0.2% Full scale ± 5C (at 50/60Hz) ±0.3% reading ± 0.2% Full scale ± 5C ± 0.1%/100Hz
    VA Meter 0.1VA / 1VA or  1VA / 10VA or  10VA / 100VA  Auto Range ±0.05% of VA range
    PF Meter 0.001

    --